VPC (Sensor direct connection type, with comparison setting 2 output)Round Digital Pressure Meter with 2 Comparison Setting type
Display: 1999 3 1/2-digit Super luminosity Red LED (Character height: Approx. 15mm)
Rated capacity: 5kPa to 100MPa, 50kPa abs to 1700kPa abs
Output: 2-setting/Relay output, 2-setting/PhotoMOS relay output
Power: AC100V [5VA], AC110V [5VA], AC200V [5VA], AC220V [5VA], DC±12V [200mA], DC24V [100mA], DC12V [200mA] * When specifying AC power, a dedicated power converter "TUC" will be included.
Fast response setting output without microcomputer.
Easy pressure setting while viewing the digital display.
High accuracy and long life.
VPC(Differential pressure calculation model with analog output)Differential Pressure type Round Digital Pressure Meter with Analog Output (Calculation Model)
Display: 1999 3 1/2-digit Super luminosity Red LED (Character height: Approx. 15mm)
Rated capacity: 5kPa to 100MPa, 50kPa abs to 1700kPa abs
Output: 1mV/digit (±1999mV.max), 1 to 5V, 4 to 20mA (4 wire system), 0 to 5V, 0 to 10V
Power: AC100V [5VA], AC110V [5VA], AC200V [5VA], AC220V [5VA], DC±12V [200mA], DC24V [100mA], DC12V [200mA] * When specifying AC power, a dedicated power converter "TUC" will be included.
Pressure is input via two sensors, requiring no equalizing valve for preventing one-side pressure resistance.
High accuracy and long life.
Digital Pressure Meter Accessories/Options
List of accessories (Manual, Test report, O-ring, Bracket, Connector, Packing)
Waterproof M type2 Comparison Setting type Pressure Switch with Internal Setting Trimmer
Rated capacity: 50 kPa to 100 MPa, 50 kPa abs to 1700 kPa abs
Output: 2 setting / Open collector output 45V 100mA
Use Temperature Range: -10 to 55 deg C (No freezing)
Use Humidity Range: 0 to 85% RH (No condensation)
Power: DC 12 V, DC 24 V
Contact output response as fast as approx. 1 ms.
High accuracy and long life.
Can be used in combination with a variety of pressure sensors.
VLC-H400Load button type load cell
Use: Load
Measurement type: Compression
Rated capacity: 50kN to 100kN
Nonlinearity: ±0.1%R.C.
Temperature compensation range: -10 to 70 deg C
Variant of VLC-H229 with molded in internal circuit to protect against damage due to vibration.
High accuracy
Robot cable (5 m, standard)
VLC-218Load button type load cell
Use: Load
Measurement type: Compression
Rated capacity: 50kN to 200kN
Nonlinearity: ±0.2%R.C.
Temperature compensation range: -10 to 60 deg C
High accuracy
Robot cable (5 m, standard)
VLC-200KNJ544Load button type load cell
Use: Load
Measurement type: Compression
Rated capacity: 200kN
Nonlinearity: ±0.1%R.C.
Temperature compensation range: -10 to 70 deg C (No condensation or freezing)
High capacity
Robot cable (5 m, standard)
VLC-087Load button type load cell (High capacity)
Use: Load
Measurement type: Compression
Rated capacity: 500kN to 1MN
Nonlinearity: ±0.2%R.C.
Temperature compensation range: -10 to 70 deg C (No condensation or freezing)
High capacity
High accuracy
VLC-E333M1HTemperature-proof Miniature Button Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 1kN to 20kN
Nonlinearity: ±0.3%R.C.
Temperature compensation range: -30 to 150 deg C (No condensation or freezing)
Heat-resistant as high as 150 deg C
Miniature design
VLC-G471M2Environment-Poof Button Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 10kN to 50kN
Nonlinearity: ±0.1%R.C.
Temperature compensation range: -10 to 60 deg C (No condensation or freezing)
Double-sealed cable connection for improved water resistance.
Suitable to tension control for paper, etc.
VLC-024AFlat type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 10kN to 100kN
Nonlinearity: ±0.5%R.C.
Temperature compensation range: -10 to 60 deg C (No condensation or freezing)
Compact and flat type easy to be attached to shafts or cylinders.
Low cost type
VLC-G811Flat type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 10kN to 50kN
Nonlinearity: ±0.5%R.C.
Temperature compensation range: -5 to 70 deg C (No condensation or freezing)
Compact and flat type easy to be attached to shafts or cylinders.
VU93Side-force Resistant Flat type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 1kN to 50kN
Nonlinearity: ±0.5%R.C.
Temperature compensation range: -10 to 70 deg C
Lateral force on surface 40 to 100% by the lateral force correction mechanism.
Double-sided flange
Low-profile design
VKMRMiniature Washer type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 20kN to 400kN
Nonlinearity: ±10%R.C.
Temperature compensation range: -10 to 70 deg C
Compact center-hole type that can be installed anywhere.
VKMR2Miniature Washer type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 20kN to 2MN
Nonlinearity: ±1.5%R.C.
Temperature compensation range: -30 to 70 deg C
Compact center-hole type that can be installed anywhere.
VLC-G510AMiniature Washer type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 20kN to 50kN
Nonlinearity: ±1%R.C.
Temperature compensation range: -5 to 60 deg C (No condensation or freezing)
Compact center-hole type that can be installed anywhere.
Robot cable (5 m, standard)
VLC-020/021Shear Web type Load Cell
Use: Load
Measurement type: Compression
Rated capacity: 10kN to 200kN
Nonlinearity: ±0.1%R.C.
Temperature compensation range: -10 to 60 deg C
Compact and low-profile
Robot cable (5 m, standard)
VLC-G787Miniature Load Cell for Manual Press
Use: Load
Measurement type: Compression
Rated capacity: Please contact us for various rated capacities
Nonlinearity: ±3%R.C.
Temperature compensation range: -5 to 60 deg C (No condensation or freezing)
Flex-resistant cable (standard)
Custom-made to different mounting dimensions available.
No minimum order quantity.
VLC-023Pin type load cell
Use: Load
Measurement type: Compression
Rated capacity: 5kN to 100kN
Nonlinearity: ±2%R.C.
Temperature compensation range: -10 to 60 deg C (No condensation or freezing)
Good environmental resistance
Abundant variations available
Suitable for crane & hoist, steel and paper
VU9CDiaphragm type Load Cell
Use: Load
Measurement type: Tensile and compression
Rated capacity: 50N to 50kN
Nonlinearity: ±0.2%R.C
Temperature compensation range: -10 to 70 deg C (No condensation or freezing)
Ultrasmall design