Pressure Transmitter

Pressure TransmitterPressure Transmitter for Flush type Middle High Pressure

1MPa~50MPa
VPRF
 *Available digital panel meters
   >>Click here for the list.

Suitable for measurement of viscous media since the flush type (no feed port) wetted part is hardly clogged up.
Wetted part constructed integral with diaphragm does not use any sealed liquid, offering durability, reliability and long life.
Abundant analog output available.
 [4~20mA(2 wire system, 4 wire system), 1~5V, 0~5V, 0~10V]

Measured medium Water, oil, gases or other media that will not corrode SUS630.
Pressure type Positive and compound pressures can be measured.
Measured Range Can be specified within the range of 1 MPa to 50 MPa of rated capacity (Calibration: 0.5 MPa to 50 MPa).
Specify more than 50% of rated capacity as the calibration range.
Output type Specify among 4 to 20 mA (2 wire system, 4 wire system), 1 to 5 V, 0 to 5 V, and 0 to 10 V.

Specification

Non Linearity ±0.5%R.C.
Hysteresis ±0.5%R.C.
Compensated Temperature Range
(Temperature of medium to be measured)
-10~50°C(No condensation or freezing)
Safe Temperature Range
(Temperature of medium to be measured)
-10~75°C(No condensation or freezing)
Temperature Effect on Zero Balance ±0.8%R.C./10°C
Temperature Effect on Load ±0.8%R.C./10°C
Safe Overload Rating 150%R.C.
Ultimate Overload Rating 200%R.C.
Insulation Resistance 100MΩ or more (DC50V)
Pressure Port Material SUS630 or 15-5PH (Precipitation hardening stainless steels) (*1)
Connection Screw G3/8
Fastening Torque 10~20N・m
Fastening Torque;Maximum 30N・m
Power Selectable: 4DC24V(±10%), 5DC12V(±10%)
*Only 24V DC available when analog output is A5.
Cable 4- or 2-core shielded (oilproof) cable 2m Standardφ6mm
Weight Approx. 300g(Cable not included)
Accessories Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy)
Aluminum packing(×1)(Copper packing × 1 for 50 MPa model only)

Model Selection

Model Selection
Selection Check Model Specification
1.Model VPRF Pressure Transmitter for Flush type Middle High Pressure
*Connection screw: G3/8
2.Analog output

*Only A6 available for waterproof terminal box type
- - Output type Response frequency Safe load resistance Consumption current
  A2 1~5V 500Hz 5kΩ or more Approx. 23mA
  A3 4~20mA
(4 wire system)
DC24V: 500Ω or less
DC12V: 250Ω or less
Approx. 40mA
  A4 0~5V 5kΩ or more Approx. 23mA
  A5 0~10V 5kΩ or more Approx. 23mA
  A6 4~20mA
(2 wire system)
1kHz DC24V: 500Ω or less
DC12V: 150Ω or less
-
3.Calibration - - Rated capacity Example of calibration range
  See right table. Enter the range in the   as it is. 1MPa 1MPa(0~1)MPa 0.5MPa(0~0.5)MPa
2MPa 2MPa(0~2)MPa 1.5MPa(0~1.5)MPa
5MPa 5MPa(0~5)MPa 3MPa(0~3)MPa
10MPa 10MPa(0~10)MPa 7MPa(0~7)MPa
20MPa 20MPa(0~20)MPa 14MPa(0~14)MPa
50MPa 50MPa(0~50)MPa 35MPa(0~35)MPa
4.Cable Connection   Blank Standard connector   Equivalent to IP40
  W Waterproof connector   Equivalent to IP56
  S Pigtail Equivalent to IP54
  T Waterproof terminal box type Equivalent to IP55 *Applicable only when analog output is A6.・Cable not included
5.Power   4 DC24V(±10%)
  5 DC12V(±10%) *Not available when analog output is A5.
6.Length(Cable)   2m 2m Standard
  3m 3m
  5m 5m
  10m 10m
  □□m Other length
*Contact our sales office for other cable lengths.