Specialized manufacturer of Digital Pressure Meters and Load Cells

VALCOM CO.,LTD.

 

Pressure Sensor
Options

Conversion adaptor

Conversion adaptor Photo Model Application pressure sensor Note
For R1/4 G3NF-R2M-S3
(G3/8 → R1/4 Material: SUS304)
Pressure sensor
of G3/8 screw
"VESV"
"VESI"
"VESIM□□T"
"VESIM□□A"
Dedicated joint of VALCOM
For R3/8 G3NF-R3M-S3
(G3/8 → R3/8 Material: SUS304)
For R3/8 G3/8 → R3/8
(Material: SUS316)
Pressure sensor
of G3/8 screw
"VPRTF"
"VPVTF"
"VPRQF"
"VPVQF"
Other companies product
For R1/4 G3/8 → R1/4
(Material: SUS316)
For R1/2 G3/8 → R1/2
(Material: SUS316)
For G1/2 G3/8 → G1/2
(Material: SUS316)
For G1/4 G3/8 → G1/4
(Material: SUS316)
For R3/8
Surge pressure absorption
J2 joint (R3/8→ R3/8 Material: SUS303)
R3F-R3M-S3 (Joint body)
FS10-013 (Throttle) (*1)
Dedicated R3/8
"VPRT"
"VPVT"
"VPRQ"
"VPVQ"
Dedicated joint of VALCOM
  • *Contact our sales office for price and delivery.
  • (*1) Combination with pressure sensor & model No.: Add "-J2" to the end of pressure sensor model No.
    Oil is sealed in the joint. Contact us separately for the kind of oil.

Protective joint against excessive pressure or surge pressure

What is the surge pressure ? When a surge pressure occurs, the peak value may be several times the normal pressure.
(More than five times in case of injection molding machines)
Surge pressure exceeding the allowable pressure may cause the sensor to break down.
Countermeasure 1. Generally, a "damper (fitting for reducing pulsation pressure)" sold by pressure meter suppliers is used.
2. When combined with VALCOM pressure sensors, a conversion adapter with orifice "J2 Joint" may be used. (See table above.)
Applicable to the VALCOM VPRT/VPVT/VPRQ/VPVQ series.
*Contact our sales office for details or questions.
Surge pressure and Countermeasure
  • * Refer to "FAQ" for the layout for avoiding impact pressure, surge pressure and water hammer to the pressure sensors.

For "Cable Unit" for the Pressure sensor

Target model (Strain gauge output)
VPRT, VPRTF, VPVT, VPVTF, VPRQ, VPRQF, VPVQ, VPVQF, VHR3, VHG3, VAR3, VAG3
VPRNP(R3/8), VPRNP(G3/8), VPNPR, VPNPG, VPRF, VNF
Target model (Process output)
VHR3, VHG3, VAR3, VAG3, VPNPR, VPNPG, VPRT, VPRTF, VPRQ, VPRQF, VPVT, VPVQ
VPRF, VNF, HS1, HV1, AS1, AV1, NS1, NV1

Makeup

Strain gauge output

Process output

Model Selection (Strain gauge output)

Example

Selection Check Model Specifications
1.Connector Type
(Sensor Side)
  K Standard connector (Made in Tajimi): PRC03-12A10-7M
  W Waterproof connector (Made in Tajimi): 1108-12A10-7M
2.Terminal Type
(Indicator Side)
  N Loose wire Standard
  T Solderless terminal (M3 Round terminal)
  K Standard connector (Made in Tajimi):PRC03-12A10-7M
3.Cable Type   S3 Standard
(φ6mm 0.3SQ×4-core braided shielded oilproof cable)
  T3 For minute pressure
(φ6.5mm 0.3SQ×4-core braided shielded oilproof cable / In tube)
  S5 For Intrinsically safe explosion-proof
(φ6.5mm 0.5SQ×4-core braided shielded oilproof cable)
  T5 For intrinsically safe explosion-proof and minute pressure
(φ8mm 0.5SQ×4-core braided shielded oilproof cable / In tube)
  KV For flex resistant
(φ8mm 0.5SQ×4-core braided shielded flex-resistant cable)
  HS For heat resistance
(φ5mm 0.3SQ×4-core braided shielded heat resistance cable
(Compensated temperature 150°C))
4.Cable length   3M 3m
  5M 5m
  10M 10m
  □□M   m Can be specified up to 100m
5.Special (Type)   Blank If none of the following applies
  CG When connected to "GV" (input) of F3/F4/F5/F6/F8/F9
  VEK When connecting to zener barrier (Terminal treatment: T)
  VEK/CG When connecting to zener barrier and "GV" input models of F3/F6/F4/F5/F8/F9 digital panel meters.
  • * Contact our sales office for the combination of pressure sensors and digital meters and selection of models.

Model Selection (Process output)

Example

Selection Check Model Specifications
1.Connector Type
(Sensor Side)
  K Standard connector (Made in Tajimi): PRC03-12A10-7M
  W Waterproof connector (Made in Tajimi): 1108-12A10-7M
2.Terminal Type
(Indicator Side)
  N Loose wire Standard
  T Solderless terminal (M3 Round terminal)
3.Cable Type   S3 Standard
(φ6mm 0.3SQ×4-core braided shielded oilproof cable)
  T3 For minute pressure
(φ6.5mm 0.3SQ×4-core braided shielded oilproof cable / In tube)
  S6 For 4–20mA 2 wire system
(φ6.5mm 0.5SQ×2-core braided shielded oilproof cable)
  T6 For 4–20mA 2 wire system
(φ6mm 0.5SQ×2-core braided shielded oilproof cable / In tube)
4.Cable length   2M 2m
  3M 3m
  5M 5m
  10M 10m
  □□M   m Can be specified up to 100m
5.Special (Type)   Blank If none of the following applies
  CN When connected to "N" (input) of F3/F4/F5/F6/F8/F9
  • * Contact our sales office for more information about the combination of pressure transmitters and cables.

Membership is required to use the download service.
If you have already finished registration, log in from here.

■ E-mail address