Digital Pressure Meter
      Product list
    
  Product list
    
    
  | Photo | Model | Display | Analog output | BCD Output | Output contact | Power | Peak hold | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power 4–20mA | Voltage (V) | Bat- tery | AC | DC | ||||||||||||
| LCD | LED | 2-wire system | 4-wire system | 1–5 | 0–5 | 0–10 | 1 point | 2 point | Free | Selec- tion | ||||||
|     | VST | - | ○ | - | ○ | - | - | - | - | - | ○ | - | ○ | - | - | ○ | 
|     | VSS-□35 | - | ○ | - | - | ○ | - | - | - | - | ○ | - | - | - | ○ | - | 
|  | VPTS | ○ | - | ○ | - | - | - | - | - | - | - | - | - | - | ○ | - | 
|     | VSW2 For Low-Absolute pressure | ○ | - | - | ○ | - | - | - | - | ○ | ○ | - | - | - | ○ | ○ | 
|     | VSW2 2-contact high capacity output For Low-Absolute pressure | ○ | - | - | - | - | - | - | - | - | ○ | - | - | - | ○ | ○ | 
|     | VSW2 Flash diaphragm sensor For Middle-High pressure | ○ | - | - | ○ | - | - | - | - | ○ | ○ | - | - | - | ○ | ○ | 
|     | VSW2 2-contact high capacity output For Middle-High pressure | ○ | - | - | - | - | - | - | - | - | ○ | - | - | - | ○ | ○ | 
|     | VSW2H High Accurate For Middle-High pressure | ○ | - | - | ○ | - | - | - | - | ○ | ○ | - | - | - | ○ | ○ | 
|  | VPG8 For Low-Absolute pressure | ○ | - | - | - | - | - | - | - | - | - | ○ | - | - | - | ○ | 
|  | VPG8 For Middle-High pressure | ○ | - | - | - | - | - | - | - | - | - | ○ | - | - | - | ○ | 
|  | VSMC Intelligent type | - | ○ | - | ○ | - | - | - | - | - | ○ | - | ○ | - | ○ | - | 
|  | Discontinued VSC High-capacity mechanical contact relay | - | ○ | - | - | - | - | - | - | ○ | - | - | ○ | - | - | - | 
|  | VPMC-A(B)-6 2-wire transmission system | - | ○ | ○ | - | - | - | - | - | - | - | - | - | - | ○ | - | 
|  | VPMC Analog output | - | ○ | - | ○ | ○ | ○ | ○ | - | - | - | - | - | ○ | ○ | - | 
|  | VPMC Comparison setting 1 output | - | ○ | - | - | - | - | - | - | ○ | - | - | - | ○ | ○ | - | 
|  | Discontinued VPC Peak hold | - | ○ | - | - | - | - | - | - | - | - | - | - | ○ | - | ○ | 
|  | Discontinued VPC Analog output BCD output | - | ○ | - | ○ | ○ | ○ | ○ | ○ | - | - | - | - | ○ | ○ | - | 
|  | Discontinued VPC Comparison setting 1 output | - | ○ | - | - | - | - | - | - | ○ | - | - | - | ○ | ○ | - | 
|  | Discontinued VPC Comparison setting 2 output | - | ○ | - | - | - | - | - | - | - | ○ | - | - | ○ | ○ | - | 
|  | Discontinued VPC Differential pressure calculation model with analog output | - | ○ | - | ○ | ○ | ○ | ○ | - | - | - | - | - | ○ | ○ | - | 
Basic operation of comparative output (Refer to the figure below and specify the model H or L.)
Models concerned: VSMC, VPMC
 
      Basic operation od comparative output of VALCOM products are as shown below.
Digital Pressure Meter
      
      
    